Seitenansicht 3
All claims made by manufacturer
PROCESSING NUMBER
COMPANY MODEL RESOLUTION TIME OF RINGS
Carl Zeiss ATLAS 0.01D; less than 22
Meditec Model 9000 submicron 1 second
Carl Zeiss Visante
omni
0.01D; seconds 22
Meditec (linking ATLAS submicron (ATLAS
with Visante OCT Placido), OCT
Model 1000) pachymetry
EyeQuip Piccolo < 1 micron < 3 seconds 28
Topographer
EyeQuip Scout < 1 micron < 3 seconds; 28
Topographer depends on
computer
EyeSys System 3000 high res computer 40
Vison, Inc. dependent
EyeSys Vista Portable high res computer 25
Vison, Inc. CT dependent
Haag-Streit CTK-922 ± 0.10 instant 22
Marco 3D Wave high res 0.4 seconds 19 vertical;
23 horizontal
Nidek Inc. OPD-Scan II, Optical high res 0.4 seconds 19 vertical;
Path Difference Diag. 23 horizontal
System, ARK-10000
Nidek Inc. Magellan high res; < 1 second 60
Mapper ± .03 mm
Oculus Inc. Easygraph ± 0.20D 1 second 22; high-res
CCD camera
Oculus Inc. Keratograph ± 0.10D 1 second 22; high-res
CCD camera
Oculus Inc. Pentacam Basic ± 0.25D max. 2 no rings;
seconds Scheimpflug
camera
Oculus Inc. Pentacam Classic ± 0.25D max. 2 no rings;
seconds Scheimpflug
camera
Oculus Inc. Pentacam HR
+/- 0.1D
1 second no rings;
(High Resolution) Scheimpflug
camera
Shin-Nippon CT-1000 High res < 2 seconds, 20
± 1.25D depends on CPU
Tomey USA TMS-4 800 x 600 3 seconds 25 & 31
pixels
Topcon Medical CA-200 +/- 0.01; < 10 sec. 24
Systems 1 micron
Topcon Medical KR-8000PA n/a n/a 10
Systems
Topcon Medical
iTrace Combo .01 diopter/1µ instant 25
Systems
Visual
Functional
Analyzer
Woodlyn/Medmont E300 High resolution none/instant 32
Ziemer GALILEI
TM
Dual +/- 0.1D 1-2 seconds 20
Ophthalmic Scheimpflug
Systems Analyzer
CORNEAL TOPOGRAPHERS
NUMBER OF WORKING FOCUSING
DATA POINTS DISTANCE MECHANISM ADDITIONAL FEATURES
thousands 70 mm Joystick with patented Proven Placido disk technology and Arc-Step Algorithm for submicron elevation accuracy. Zernike corneal wavefront analysis for
Cone of Focus
aspheric IOL selection, image simulation of higher order corneal aberrations, invisible ring illumination for patient comfort; auto
alignment system pupillometry (scoptopic & photopic) and white to white (HVID) measurement. PathFinder II Corneal Analysis Software screens for 5
and Smart Capture
different corneal conditions with >92% accuracy. MasterFit II CL fitting module. Small footprint, integrated Win XP computer with
Technology DVD-ROM/ethernet/USB. ATLAS comes with the onboard functionality to connect to FORUM Data Management system. FORUM allows
real-time viewing of reports or images from supported networked
ZEISS
and non-
ZEISS
instruments. FORUM supports bi-directional
workflow for supported DICOM enabled devices, reducing charting errors and increasing patient throughput.
thousands 47 mm V-Trac
Only combined Placido + OCT system for anterior and posterior corneal topography including the Holladay Report; complete anterior
Registration System segment imaging with full pachymetry map, anterior chamber angle and diameter measurements, corneal flap thickness
measurement; Refractive Tools Software for surgical planning; Irido-Corneal Tools Software to quantify angle anatomy; Topography
Link Software compatible with ZEISS ATLAS Models 993, 995, and 9000. Visante
omni
comes with onboard functionality
to connect to FORUM Data Management system. FORUM allows real-time viewing of reports or images from supported networked
ZEISS
and non-
ZEISS
instruments. FORUM supports bi-directional workflow for supported DICOM enabled devices, reducing charting
errors and increasing patient throughput.
7,168 measured <10 mm patented infrared
Corneal wavefront mapping clearly displays corneal spherical aberration and low and high order aberrations that can be
75,000 analyzed vertex detector
removed from the map individually; slit lamp or table top mount; use your laptop or desktop computer; Exclusive Wave
Contact Lens Design Software included.
7,168 measured <10 mm patented infrared Std. corneal wavefront mapping clearly displays low & high-order aberrations that
can be removed from the map individually;
75,000 analyzed vertex detector
opt. IR pupillometry; three interchangeable opt. IR pupillometry; three interchangeable Scout models; portable w/battery; slit lamp
mounted or table-based w/a permanent headrest; use your laptop or desktop computer; exclusive Wave Contact Lens
software designs custom RGP & soft lenses .
up to 14,400 32 mm 3 camera apex New desktop topographer/pupillometer. Solid state USB 2.0 digital design, patented high-resolution, 3-camera technology and
detection with patented multi-resolution, adaptable ring placido. Many options include corneal wavefront high-order aberration map,
auto-capture Holladay diagnostics, white to white measurement, etc.
9,000 12.5 mm image sequence Newly updated for 2008. Portable, fast and easy-to-use, solid state USB 2.0 digital design, no moving parts, automatic exam
through focus acquisition, map options include corneal wavefront high order aberration map, Holladay diagnostics,
auto-capture white to white measurement, etc
22,000 80 mm joystick Keratometer built-in; contact lens software;
3-D
image; keratoconus detection; Fourier and Zernike analysis.
6,480 75 mm XYZ axis fully Diopter range is on Ct. 10 to 100D out to 11 mm; more than 6,800 data points, includes axial, tangential, refractive & elevation
automatic alignment maps; ARK; Angle Kappa, spherical aberration of cornea, wavefront analyzer; OPD; internal OPD; pupillometer; mesopic &
photopic pupil displayed; Windows XP embedded; Celeron M1.5 GHz Processor; EMR-ready through Marco Connect.
6,480 or more 75 mm XYZ axis fully Diopter range is on Ct.10 to 100D out to 11 mm; includes: axial, tangential, refractive & elevation maps; objective autorefraction &
automatic alignment wavefront analysis technology via dynamic skiascopy; wavefront maps include: OPD, Zernike polynomial graphs, total
wavefront aberration & wavefront higher-order aberration.
21,600 1.5 mm XYZ joystick w/auto- Klyce Corneal Navigator Screening Program aiding in the detection of nine corneal conditions; Corneal Aberrometry Software;
offset correction NAVIS EMR included.
22,000 40 mm automatic focusing; Exclusive “REAL” keratometer built in; image data transferred digitally to computer; Windows-compatible software;
3-D
;
manual override overview image; Fourier analysis; height & refractive maps std.; keratoconus detection software; Zernike analysis software &
contact lens fitting software opt.; contact lens software includes 35,000 lens database & fluor. image-simulation; ortho-k
software also available. OxiMap Software shows the “breathability” of the contact lens.
22,000 80 mm automatic focusing; Exclusive “REAL” keratometer built in; image data transferred digitally to computer; Windows-compatible software;
3-D
;
manual override overview image; Fourier analysis; height & refractive maps std; keratoconus detection software & Zernike analysis software;
contact lens software includes 35,000 lens database & fluor. image simulation; refractive comparison software for corneal
refractive therapy; opt. pupillometry software avail. New Tear Film Scan Software analyzes the tear film retention of the cornea
and OxiMap Software shows the “breathability” of the contact lens.
25,000 true 80 mm automatic focusing; The Pentacam Basic is a rotating Scheimpflug camera system that includes the basic software modules that a practice needs for
elevation pts. manual override day-to-day use. Topography and elevation of the anterior and posterior surfaces of the cornea and pachymetry are seen in the
basic software that includes the Overview Display, 1 Large Color, 4 Maps Refractive, Scheimpflug Image, Virtual Eye, Tomography,
Topometric and the ability to Compare 2 Exams. Optional software includes Refractive Software Package, Cataract Software
Package, the Holladay Report and Belin/Ambrosio Enhanced Ectasia software.
25,000 true 80 mm automatic focusing; The Pentacam is a rotating Scheimpflug camera system; anterior & posterior corneal topography; anterior segment/chamber
elevation pts. manual override analysis; calculates chamber angle in degrees, camera chamber volume, diameter & height; creates moveable 3-D model;
images anterior & posterior corneal surfaces, iris & the lens; quantifies & diplays crystalline lens opacifications; measures
IOL vault distance from any eye surface; detects optimal focus for anterior chamber imaging, Holladay Report with Equivalent K
Readings for better IOL Calculation; 1 year free software upgrades.
138,000 true 80 mm automatic focusing;
The Pentacam HR is a rotating Scheimpflug camera system; anterior & posterior corneal topography; anterior segment/chamber
elevation pts. manual override
analysis; calculates chamber angle in degrees, camera chamber volume, diameter & height; creates moveable 3D model;
images anterior & posterior corneal surfaces, iris & the lens; quantifies & displays crystalline lens opacifications; measures IOL
vault distance from any eye surface; detects optimal focus for anterior chamber imaging, Holladay Report with Equivalent K
Readings for better IOL Calculation; 1 year free software upgrades.
6,344 6 mm joystick w/automatic Joystick alignment w/automatic measurement; compact design; user-friendly; easily updated software; axial, tangential,
measurement elevation, refractive, multiple,
3-D
maps; comparison maps; small cone/larger measuring zone; contact lens fitting
software with fluoro image stimulation.
8,000 70 mm joystick Provides spherical equivalent, regular astigmatism, asymmetry & higher-order alignment; provides refractive information w/3-mm &
6-mm diameter range; keratoconus screening. Klyce statistics; enhanced height & height change maps; contact lens software
and dry eye software included. Placido cone.
10,000 measured 80mm auto focus and auto Complete corneal surface analysis; on board state-of-the art PC allows for complete stand-alone operation; 8-inch touch screen panel;
points alignment WiFi communication with PC-based software; automatic “best image capture”; automatic pupil recognition; Keratoconus Index;
additional modules available including contact lens fitting and Zernike analysis.
3,600 85 mm automatic alignment Tri-functional autorefractor/keratometer w/corneal mapping & contact lens fluorescein simulation fitting program; interfaces
w/manual override w/Topcon computerized lensmeters and CV-5000 vision tester.
9,000 20 mm
laser vertex
5-in-1 functionality including ray tracing wavefront aberrometry, multi-zone auto refraction, auto-keratometry,
pupillometry; topography enabled by EyeSys Vision; provides corneal spherical aberration measurement for
IOL selection; measures lenticular aberrations; keratoconus screening; asphericity index; computer-independent.
15,000 30 mm joystick with progressive Instrument is controlled via PC, which allows for easy networking in your office and integration with your EMR or PM software.
measured points auto capture and 4 Software allows you to view exams in 2D or 3D. Fully automatic image capture keeps patient testing both fast and simple.
simultaneous captures Images are captured automatically with a simple built-in alignment system. Simply position the instrument, guided by the
so you never have to intuitive 3D focusing target, and let the software do the rest.
repeat the test
>122,000 58 mm computer-aided 3D GALILEI
TM
is the only device on the market that combines a Placido-Disk System with a dual-rotating Scheimpflug Camera and
alignment merges all data from its two subsystems to generate a high-precision 3D map of anterior and posterior corneal surfaces and of
the anterior segment. Features Ray Tracing for high-precision Total Corneal Power-based calculations of IOL Power in
post-refractive eyes, and advanced keratoconus diagnostics.
Seitenansicht 3
1 2 3 4 5 6 7 8 9 10 11

Kommentare zu diesen Handbüchern

Keine Kommentare