MEASUREMENT
COMPANY MODEL TYPE RANGE
Accutome Accupen Handheld contact, 5 to 60 mmHg
Tonometer applanation
Canon Medical TX-F Full Auto fully automated; 0 to 60 mmHg
Systems Tonometer just press start
Gulden Ophthalmics Schiotz contact 0 to 127.5 mmHg
Haag-Streit USA Goldmann Applanation applanation 0 to 80 mmHg
Tonometer AT 870
Haag-Streit USA Goldmann Applanation applanation 0 to 80 mmHg
Tonometer AT 900
Haag-Streit USA Perkins Mk2 Handheld applanation n/a
Applanation Tonometer
Icare USA Icare TA0i tonometer rebound 7 to 50 mmHg
Keeler Pulsair Easy Eye noncontact 7 to 50 mmHg
Instruments Noncontact Tonometer
Kowa KT-800 Noncontact noncontact 0 to 60 mmHg
Optimed Inc. Tonometer
Kowa HA-2 applanation 0 to 60 mmHg
Optimed Inc.
Marco M3 noncontact 0 to 60 mmHg
Marco NT-510 noncontact 0 to 60 mmHg
Paradigm Medical Ocular Blood applanation IOP measurement: 6
Industries Flow Analyzer high: no upper limit
(BFA)
Reichert Technologies CT100 Applanation Tonometer applanation 0 to 80 mmHg
Reichert Technologies CT210 Applanation Tonometer applanation 0 to 80 mmHg
Reichert Model 30 contact 5 to 80 mmHg
Technologies
Pneumatonometer
applanation
Reichert Tono-Pen XL contact 5 to 80 mmHg
Technologies applanation
Reichert
PT100 Portable noncontact 0 to 60 mmHg
Technologies NCT
Reichert Ocular Response noncontact 1 to 60 mm Hg
Technologies Analyzer
Reichert Tono-Pen AVIA contact 5 to 55 mm Hg
Technologies applanation
Reichert Technologies Reichert 7 noncontact 7 to 60 mm Hg
Reichert Reichert 7CR Auto Non- noncontact 7 to 60 mmHg
Technologies Contact Tonometer + Corneal
Response Technology
Shin-Nippon B-45 applanation 0 to 80 mm Hg
Shin-Nippon C-84 applanation 0 to 80 mm Hg
Tomey FT-1000 noncontact 0 to 60 mm Hg
Topcon Medical CT-80 noncontact 0 to 60 mm Hg
Systems
Woodlyn Inc. #44000 R900 applanation/ 0 to 80 mm Hg
Goldmann
Ziemer Ophthalmic PASCAL Dynamic Contour contact dynamic 5 to 200 mm Hg
Systems Tonometer color
Ziemer Ophthalmic Wireless PASCAL Dynamic contact dynamic 5 to 200 mm Hg
Systems Contour Tonometer color
All claims made by manufacturer
ALIGNMENT
COMPANY MODEL TYPE MONITOR
Stereo Optical Optec 5500(P) stand-alone yes
Co. Inc. vision tester;
requires 2 sq. ft.
Stereo Optical Optec 5000(P) stand-alone yes
Co. Inc. vision tester;
requires 2 sq ft.
Stereo Optical Optec 1000P stand-alone yes
Co. Inc
VectorVision Inc. CSV-1OOO stand-alone; 8 to 4 meter 3 choice;
test distance from exam 4 frequency
chair; non-view-in sine wave
ALIGNMENT PORTABILITY/WEIGHT OPTIONS SPECIAL FEATURES
manual handheld, portable 3.0 oz n/a Ergonomic design with gravity offset technology, providing accurate IOP measurements and no calibration.
Long-lasting battery - 15,000 measurements.
full auto/ 45.2 lbs. Up to 10 measurements per eye; includes automatic shifting between 30/60 mm Hg; IOP warning; extremely
manual soft air puff; RS232C data output.
manual 0.5 lbs. Very portable; lightweight; great for emergency use; inexpensive; durable.
manual slit lamp mounted
manual slit lamp mounted
manual handheld
manual 8.8 oz (250 g) Easy to use, handheld tonometer for accurate & patient-friendly IOP measuring without anesthesia.
manual yes, weighs less carrying case; Wall, desk or slit-lamp mountable; accuracy within
±0.6 mm Hg Goldmann, Soft Puff technology &
than 9 lbs. rechargeable battery
built-in printer.
3D automatic tabletop/instrument optional 3x long eye relief 3-D auto alignment function; soft airflow, no measurement range switching; eyelid obstruction
alignment stand 39.6 lbs. for presbyopic users monitor; electronically operated chin rest; built-in
video camera & TFT color 5.6 monitor for ease of use.
manual handheld/battery optional 3x long eye
operated 0.53 lbs.
relief for presbyopic users
manual or desktop unit Softer air puff; measures pupil size & corneal size; autorefractor/keratometer, adjustable monitor; motorized
automatic automatic (55 lbs.) chin rest; high speed measurements; interfaces w/EPIC, TRS & Evolution.
manual or desktop unit (42 lbs.) printer, rechargeable Advanced soft-air pulse control; automatic safety lock.
automatic battery comes std.
manual portable; console: 12 lbs. printer; slit-lamp Identify POAG & NT; identify glaucoma suspects w/low pulsatile ocular blood flow (POBF); identify central retinal
workstation: 23 lbs. adaptability vein occlusions; monitor & quantify the effect of glaucoma treatment plans; measure IOPs & POBF by volume;
monitor & manage current systemic drug therapy.
manual slit lamp mounted Fits most tower-type slit lamps.
manual slit lamp mounted Fits most compact-type slit lamps.
manual 12 lbs. tonography An easy-to-use instrument providing fast accurate tonometry & opt. tonography functions. The system measures
IOP in the range of 5 to 80 mm Hg. Forty readings per second are recorded & charted, including ocular pulse.
The chart recorder produces a permanent printout of the desired test for patient files.
manual 2.25 oz. An easy-to-use portable, handheld instrument providing fast & accurate intraocular pressure readings w/accuracy
comparable to the Goldmann tonometer. Harvesting data at a rate of 500 samples per second, the Tono-Pen gently
contacts the cornea & displays the average of four independent readings, along w/a statistical coefficient.
manual handheld/portable; wireless IR printer; carrying Cordless, wireless data transmission; patient eye illumination; demo puff; icon-based operating system;
2.7 lbs. case; re-chargeable battery; macroview of eye.
charging base
automatic tabletop/instrument Measures IOP & Corneal Hysteresis (CH), the world’s first indicator of corneal biomechanical properties, & IOPcc
stand 30 lbs. (corneal compensated IOP), which is less affected by corneal properties than traditional methods of tonometry.
manual handheld, portable n/a Portable, light & user-friendly. Provides fast measurements, strongly correlated w/Goldmann tonometry.
71 g. Long battery life, w/no need for calibration. Ergonomic design provides maximum comfort & ease
of use & large LCD screen display readings on both sides of instrument.
automatic tabletop/instrument stand 30 lbs. internal printer Demo puff, icon-based operating system, softest puff in the industry, full auto-alignment and 1-touch operation.
automatic tabletop/instrument Demo puff, icon-based operating system, industry’s softest puff, full auto-alignment and 1-touch operation.
stand 30 lbs. Patented corneal response technology compensates for the biomechanical properties of the cornea, providing
IOPcc, a measure of intraocular pressure that is less influenced by corneal properties than other tonometers.
manual slit lamp accessory, 1.42 lbs. n/a Fits most tower-type slit lamps.
manual slit lamp accessory, 1.4 lbs. n/a Fits most compact-type slit lamps.
full auto 18 kg / 39.7 lbs. n/a Touch alignment. Gentle air noise assures patient is examined comfortably. Measurement lag time of 15 ms
reduces measurement errors.
manual/ about 18 kg or optional adjustable Built-in video camera & monitor; auto measurement, digital display & built-in printer; triple safety function;
automatic 39.7 lbs. instrument table dual sensor system & 30% faster interval time.
manual mounts to slit lamp;
1.33 lbs.
manual 1 lb. carrying case; rechargeable Provides highly accurate IOP; Ocular Pulse Amplitude & Quality score; IOP not affected by corneal biomechanical
batteries properties; validated in in-vivo clinical trials; easy to use; www.pascal-tonometer.com
manual 1 lb. wireless printer; carrying Provides highly accurate IOP; Ocular Pulse Amplitude & Quality score; IOP not affected by corneal biomechanical
case; rechargeable properties; validated in in-vivo clinical trials; easy to use; digital display w/option of using wireless printer;
batteries EMR ready.
TONOMETERS & BLOOD FLOW ANALYZERS
CONTRAST SENSITIVITY TESTS
CONTRAST DAY/NIGHT TARGET DAY/NIGHT GLARE
SENSITIVITY TYPE ILLUMINATION LUMINANCE ADDITIONAL FEATURES
3-choice, 5-frequency sine-wave (FACT) or day only (factory calibrated); no glare Features distance/near lens system; choose from 150 different tests
low-contrast letters (CAT) homogenous illumination that can include distance/near Snellen acuity (ETDRS format) color,
stereo test, lateral/vertical phoria & potential acuity.
3-choice, 5-frequency sine-wave (FACT) day only (factory calibrated); no glare Features distance/near lens system; choose from 150 different tests
or low-contrast letters (CAT) homogenous illumination that can include distance/near Snellen acuity (ETDRS format) color,
stereo test, lateral/vertical phoria & potential acuity.
3-choice, 5-frequency (FACT) day only (factory no glare Distance only w/Snellen acuity.
or low-contrast letters (CAT) calibrated)
self-calibrated light self-calibrated light yes Wireless remote control; interchangeable test faces; everything
instrument (patented) box (patented) from contrast gratings to pediatric symbols; ETDRS acuity.